APPLICATIONS:
Traffic Signals Gel filled instrumentation cables for traffic signal installations.
PRODUCT FEATURES:
- UV resistant
- Flame retardant
- Heat, oil and chemical resistant (see Chemical Rating Chart).
CONSTRUCTION:
Conductor Annealed plain copper stranded (Class 2).
 Insulation LDPE.
 Cable Filler Transparent LDPE.
 Water Block Material Gel filled with water block tape to AS/NZS 2276.2.
 TCGEL-ES (Individual Pair Screen) PET+ Aluminium/Polyster tape screen applied with 7/0.25mm TC drain wire complete with gel compound.
 TCGEL (Overall Screen) Aluminium/Polyster tape screen applied with 7/0.25mm TC drain wire and gel compound.
 Screening Collective shield of aluminium/polyester foil complete with tinned copper drain wire (7/0.25mm tinned copper). 
 Sheath PVC 4V-75.
CHARACTERISTICS:
Operating Temperature Range Fixed -20°C to 70°C.
 Maximum Conductor Temperature 70°C (Current ratings are based on 30°C air temp. See technical section for de-rating factors).
 Max. Conductor Resistance 13.6 Ω/kM.
 Min. Insulation Resistance 20G Ω/kM @ 500Vdc.
 Mutual Capacitance 65-80nF/kM @ 1kHz.
 Max. Water Penetration 3% Maximum variation of C3 between cores.
 Rated Voltage 300V.
 Minimum Bending Radius 12 x cable diameter.
 Sheath Colour Black.
 Standard Core Colour  
 PAIR 1: Blue, Blue with White Stripe.
 PAIR 2: Orange, Orange with White Stripe.
 PAIR 3: Green, Green with White Stripe.
 PAIR 4: Black, Black with White Stripe.
 NOTE: THE CABLE HAS A PAIR TO NUMBER MARKING ON THE SHEATH FOR IDENTIFICATION PURPOSES.
 Relevant Standards AS/NZS 2276.2 (exception to overall diameter for 2 & 4 pair cables), AS/NZS 1125, AS/NZS 1660, AS/NZS 1049 and ROHS Compliant.
 
 