- Overall And Individual Foil Screened Marine Data Cable Fixed Applications. XLPE/SHF 75°C. Plain Copper. Type HFX-ISOSU. Halogen Free.
|
 |
- Conductor Annealed wires of plain copper stranded IEC 60228 Class 2
- Insulation HF-XLPE X90
- Laying Up Cores in twisted pairs or triples
- Screening Individually screened pairs, triples or quads plus collective shield of aluminium/ polyester tape c/w tinned copper stranded drain
wire and synthetic tape
- Sheath SHF1 Low Smoke Halogen Free
|
 |
- Temperature Range Fixed -15 to 75°C
- Rated Voltage 0.5mm² - 60V / 0.75 to 1.5mm² - 250V (Not suitable for mains connection)
- Minimum Bending Radius Fixed 8 x cable diameter
- Sheath Colour Orange
- Standard Core Colours Numbered Black and Blue Pairs
- Maximum Conductor Temperature 90°C
- Other Flame retardant. UV stabilized. Heat, oil & chemical resistant. Low smoke halogen free
- Certification Society Approvals A.B.S., LLOYDS, B.V., DNV, RINA
- Relevant Standards IEC 60228 CL.2, IEC 60092-3-375, IEC 60332-1-3A ,IEC 60332-3A, IEC 60754-1-2, IEC 610034-1-2, CE Directive
72/23/EEC
|
 |
- For marine data applications where a plain copper conductor with overall foil screen and individual pair or triple screen fixed wiring cable with
certification society approval is required. Low Smoke Halogen Free sheath.
|
|
|
|
|
|