- Single Core Double Insulated Flexible Rubber Cable. EPR/CPE 0.6/1Kv 90°C. Tinned Copper. Harmonised Standard. Submersible 500 Metres
NOTE: FirstFlex HOS-Plus series is rated for 90°C and has tinned connductors. (Most HO7R-NF cable are only rated 60°C and have plain
copper conductors).
|
 |
- Conductor Annealed fine wires of tinned electrolytic copper stranded for HIGH flexibility VDE 0295 Class 5
- Insulation EPR Type IEP3 R90 (Equiv. 3G13 DIN VDE 0207-20)
- Sheath CPE Elastomer Rubber (CM3 Equivalent 5GM3 according to DIN VDE 0207-21)
|
 |
- Temperature Range Fixed -40 to 90°C / Flexing -30 to 90°C
- Rated Voltage Uo/U 0.6/1Kv Max AC Operating Voltage Uo 0.7Kv
- Minimum Bending Radius Fixed 4 x cable diameter / Flexing 6 x cable diameter
- Sheath Colour Black
- Maximum Conductor Temperature 90°C
- Other Flame retardant and UV Stabilised. For use in locations subject to Explosion Hazards DIN VDE 0165. Water and moisture resistant.
Suitable for permanent Submersion to 500 Metres. Heat, oil and chemical resistant. Resistant to environmental factors like oxidation, ozone,
sunlight. Very good behaviour to variations of outdoor temperature. Good tensile strength, tearing strength, and abrasion resistance
- Relevant StandardsDIN VDE 0295, DIN VDE 0207-20, DIN VDE 0207-21, DIN VDE 0165, IEC 60332-1, AS 3116, Generally to AS/NZS
5000:2003 & AS/NZS 60079, CE Directive 72/23/EEC
|
 |
- Power - Switchboards, flexible droppers from busbars, transformers, load banks or other equipment requiring fixed or flexible wiring.
Automotive - Battery leads or jumpers, battery chargers, electric forklifts etc. Marine - In marine and other areas where tinned conductors
are required. Suitable for submersible pumps. Generator Sets - As leads and for temporary power supplies. For outdoor use and in locations
subject to explosion hazards DIN VDE 0165.
|
|
|
|
|
|